The following equipment is for sale, used but in good working conditions.
We can ship it all over the world, just request a shipping quotation.
If you are interested, please email me and we will talk about it.


Can't find what you are looking for?  Click here >> more <<
 Hewlett Packard 5328A
Universal Counter 
 Options Installed:  H99/011/042
Price: $350.00 
 

The 5328A Universal Counter makes frequency, period, multiple point average, time    interval, time interval average, totalize, ratio, voltage and electronically controlled totalize measurements. Burst and CW measurements to 100MHz. Resolution of 100 ns single shot time interval measurements. Time interval averaging has a resolution better than 10 ps for repetitive time intervals as short as 100 ps. Marker outputs (operational to 100MHz) shows real time triggering for use with oscilloscope monitoring. Timebase is 10MHz with stability <3x10E-07 per month. 9-digit display with 9th digit used only with channel C functions and zero suppression to left of reading. Switchable x1 and x10 attenuators for each of the two inputs. Channel C goes up to 500MHz.

  Manufacturer's  Options  Descriptions:
            Option 010 = High Stability Time Base
            Option 011 = HP-IB Interface
            Option 020 = DVM
            Option 021 = High Performance DVM
            Option 030 = 512MHz Channel C
            Option 031 = 1300MHz Channel C
            Option 040 = High Performance Universal Module
            Option 041 = Programmable Input Controls Module (requires Option 011 for HPIB use)
            Option 908 = Rack Flange Kit for use w/o front handles
            Option 913 = Rack Flange for use with supplied front handles
            Option H99= Militarized Version
 


 Hewlett Packard 5328A
Universal Counter 
 Options Installed:  H99/011/020/041
Price: $390.00 
 


Picture not show the option 020 (DVM)

The 5328A Universal Counter makes frequency, period, multiple point average, time  interval, time interval average, totalize, ratio, voltage and electronically controlled totalize measurements. Burst and CW measurements to 100MHz. Resolution of 100 ns single shot time interval measurements. Time interval averaging has a resolution better than 10 ps for repetitive time intervals as short as 100 ps. Marker outputs (operational to 100MHz) shows real time triggering for use with oscilloscope monitoring. Timebase is 10MHz with stability <3x10E-07 per month. 9-digit display with 9th digit used only with channel C functions and zero suppression to left of reading. Switchable x1 and x10 attenuators for each of the two inputs.  This unit includes the DVM feature. Channel C goes up to 500MHz.


 Hewlett Packard 4972A
Local Area Network 
Data Analyzer
 Options Installed: 
Price: $400.00 

The 4972A LAN Protocol Analyzer captures and displays frames integral to communication between network systems and devices. Can be used for ETHERNET, IEEE, 802.3, and StarLAN local area networks (with appropriate interface). Statistical measurements provide information on fundamental parameters that instantly characterize network performance. Messages can also be transmitted in order to test system responses or simulate heavily loaded network conditions. Also can simultaneous transmit and receive.

  Manufacturer's  Options Description:
      Option 001 = RGB Color Output
      Option 002 = RS-232/V .24 Remote Interface
      Option 005 = StarLAN Interface
 


 Hewlett Packard 5334B - Digital Panel
Universal Counter 
 Options Installed: 
Price: $390.00 

Logically laid-out front panel with simple push-button design makes the 5334B Universal    Counter one of the easiest counters to use…its capabilities make it one of the most usable    counters available. High performance starts with two matched 100MHz input channels and    displays with 9 digits per second resolution. You'll find the features and abilities of this counter are endless- with the push of a button, automatic rise/fall time, pulse width and   AC/DC voltage measurements, auto triggering and auto attenuation, as well as frequency and period measurements, time interval and time interval delay, external arming/gating for synchronizing measurements to external events, plus much more! Of course, all of this power is available via the front panel or automated using the built-in HP-IB interface. Other freat features include the ability that enables the operator to store & recall up to 10 front-panel setups. 

   Manufacturer's  Options Description
      Option 010 = Oven Oscillator
      Option 030 = Channel C
      Option 060 = Rear Terminals
      Option 907 = Front Handle Kit
      Option 908 = Rack Mount Kit for use with front handles removed
      Option 909 = Front Handles and Rack Mount Kit
 


 Hewlett Packard 5382
Universal Counter 
 Options Installed: 
Price: $220.00 

The HP 5382A Electronic Counter covers the wide frequency range of 10Hz to 225MHz while offering sensitivity of 25 mV rms (30Hz to 10MHz) and 50 mV rms (10Hz to 225MHz). Input impedance is 1 Mohm, <40 pF and input attenuation is selectable between x1, x10, and x100.  Resolution is direct count: 1Hz in 1 sec and gate time is 0.1 sec, 1 sec and 10 sec. 8-digit LED display provides good resolution and non significant zero blanking. Rear panel input sensitivity of 250 mV rms. Timebase frequency is 10MHz.


 Fluke 1910A
Universal Counter 
 Options Installed: 
Price: $220.00 

The Fluke 1910A is a single channel Frequency Counter from 5Hz to 125MHz in a 1MOhm input impedance.  Attenuation button and Trigger Level potentiometer allows easy adjustment to the incomming signal.  Functions of Frequency, Period, Total Counter and Check Clock, in ranges of last digit of 100Hz, 10Hz, 1Hz, .1Hz and Automatic. Period reading selection for 1x10E0 up to 1x10E+3.  A reset button is used to clear the counting registered. 7 red led displays announce in good light, while other led indicators on panel shows scale and function under effect. Input ca goes up 250V RMS max.


 GoldStar FG-8002
Function Generator 
 Options Installed: 
Price: $215.00 


Price $215.00 plus Shipping and Handling $24.00 to Continental USA.
Click [Buy Now] button above and pay via PayPal or Credit Card.

The GoldStar function generator generates sine, triangle, square, ramp, ttl pulse, skewed sine wave under button selection, in 7 ranges from 0.02Hz to 2MHz.  Two BNC outputs for TTL output and Variable level in 50 ohms.  5 potentiometer knobs adjust Output Level (20Vpp - open, 10Vpp -into 50 ohms), Offset (DC Offset voltage from 0 to ±10V can be superimposed to output waveform), Pulse shape (Variable waveform/duty cycle symmetry) and Sweep width ( Linear sweep from 1:1 to 100:1) and Sweep Rate. This knobs works with "pull to activate", while down it assume internal set. There is a BNC front connector for VCF input, that allows the unit to receive external clock. A large multiturn (6 turns) knob is used to adjust the output frequency from 0 to 2, with large marks for 2/10 and small for 1/10 of the full scale range.  Power on and led button on front.  Unit in very good condition like new. No manual. Just power on cable. Power: 110/220Vac 50/60Hz, 20W - Size: 10Lx8Wx3H inches, 5.4lb

 Hewlett Packard 1630D
Logic Analyzer 
 Options Installed: 
Price: 890.00 
 

The 1630D Logic Analyzer has also been called the "general purpose tool for the modern designer" and for good reason! State listings and waveforms provide displays and windowing of address, data, status, and control line activity.   Selectable display modes include binary, octal, decimal, hexadecimal, ASCII, relocation, user-defined mnemonics, and microprocessor specified mnemonics.
Features:  43 channels,  State Analysis: 25MHz, 1 k memory, 3 clocks, demultiplexing,  Timing Analysis: Speeds up to 100MHz, 16 channels, Glitch triggering,  Complete programmable control, includes HP-IB & HP-ILText


 Hewlett Packard 
Model 
 Options Installed: 
Price: $ 
  Text  

 Hewlett Packard 
Model 
 Options Installed: 
Price: $ 
  Text  

 Hewlett Packard 
Model 
 Options Installed: 
Price: $ 
  Text  


Conditions:  We charge a 8% for packing and shipping time, well this can change a little. Payments need to be done in advance via money order, credit card, check (takes up to 10 days to clear at the bank), or bank wire transfer (the most common for international orders). Shipping: We ship the units in new card boxes with foam padding protection, in the next 48 hours of the payment receiving. It is not common to have operator or technical manual, but we can request a copy if you want (around extra $15). Packing and Shipping cost will be informed based on the destination location. International Shipping requires better packing padding and according with the destination country, it requires special paperwork as pro-forma invoice, that we can supply in advance.  Characteristics: The units are used, or new when noticed, but this kind of instrumentation was build rock solid to work practically forever. Good brands as HP or Tek does it with golden contacts in all cards or connectors, so you never worry about it. Some accurate units have a small oven to heat the oscillator to a very stable temperature, so the drift is almost zero. Previous Owner:  Some units come from government or some other institution auctions when they exchange it for a new technology, so it was working on a bench of some submarine or laboratory.  Even that this kind of units are robust enough, people use it in inside, laboratory bench, normally with air conditioned where smoking is forbided, and the user normaly is an experienced electronics technician, so the units were used with "respect" from a technical hand and well mantained.